Our continuous dry verge system for slate roofs has become the roofers first choice.
Slate roof gable end detail.
Should they sit flush with the gable end brickwork just inside the brickwork or overlap the brickwork.
Thick and the overhang from the side wall set between 12 in.
Close we use cookies to make your experience on our website better.
Slate finishing detail on gable end it s an end terraced house.
The cant raises the butt end of the starter course and the first full course to the same plane or angle as the following courses above.
Roof pitch the angle of a roof not only determines what slates to use but the amount of overlap that the slate roof needs to remain waterproof.
One coat is all that is needed.
Avoid gable ends that are over 8 in.
2 finish slating as close to timber roll as possible.
I prefer to install the gable drip edge under the felt though that detail is less critical than at the lower roof edge or eaves.
Lead slates chimney flashings back gutters apron and side flashings.
To 18 in depending on the style of the building.
Apply the oil before any rain and at the end of the day s work.
Code 4 lead sheet is normally used for this work and it.
Cor var1 roof 2 wall vent detail cor var2 roof 2 wall vent with masonry wall.
The slate nearest the hip slate must remain a full slate.
In this segment we will show some common details used for eave cants and gable rake edging.
At the right of the roof along the gable end we see more drip edge being used to flash the roof gable end fascia trim and roof edge.
Wide especially when the eave overhang is less than 12 in.
Where exactly should the last row of slates sit on the gable end.
No 1 manufacturer and supplier of slate dry verge systems in the uk.
All slate roofs require a cant strip at the eave.
Tile slate detail drawings.
The cant strip is variable in thickness according to the thickness of the slates being installed thicker slates require a thicker cant strip.
Sv 3 sv 5 detail around wood windows sv 3 sv 5 detail around vinyl windows gable end rain screen detail vertical siding w sturdi batten sv3 shingle or shake siding w sturdi batten sv3 panel siding w sturdi batten sv3.
Slating terms and phrases if you are not a seasoned roofer some of the terms used for slates batten spacing or overlapping of the slates can add to the confusion.
The above illustration shows basic installation details for a traditional standard thickness slate roof.
Fixing sequence with lead roll hip 1 fix 600 mm wide underlay overlapping the main underlay.
3 cover the timber roll with code 6 lead strips 450 to 500 mm wide and 1 5 to 1 8 m long.
When designing a gable end eave without a return the dimensions to look at are the width of the trim set between 6 in.
Gable edge projection and drip edge projection can also vary somewhat.